[Underfloor Heating Construction Example] PTC Poka and Underfloor Wiring Connection
Drill a hole in the base for the sheet's power wiring, drop the wire under the floor, and connect it underneath the floor.
The opened hole will be sealed with waterproof tape. The wiring lowered under the floor will be connected to a dedicated cable with a connector (extension wire). The connected connector part will be insulated with self-fusing butyl. Additionally, the cable will be supported so that it does not touch the ground. For each circuit, the connected cable will be pulled up from under the floor through a hole made in the subfloor, so that it is inside the wall of the controller installation area. Once the interior work is completed, the controller will be installed, and that will be the end of the process. *For more details, please download the PDF or feel free to contact us.